Anhui, China
Business Type:
Manufacturer/Factory, Trading Company
Registered Capital:
10000000 RMB
Management System Certification:
ISO 9001
Main Markets:
North America, South America, Eastern Europe, Eastern Asia, Western Europe
Average Lead Time:
Peak season lead time: within 15 workdays
Off season lead time: within 15 workdays
OEM/ODM Service
Sample Available

Flow Totalizer, Flow Integrator, Flow Meter manufacturer / supplier in China, offering Flow Totalizer for Flowmeter, Water Turbine Flow Meter with Stainless Steel for Water Oil Fuel Diesel Methyl Alcohol Clean Liquid, Electromagnetic Flow Meter for Water/Sewage/Slurry/Acid/Alkali and so on.

Diamond Member Since 2018
Audited Supplier
  • Flow Totalizer for Flowmeter
  • Flow Totalizer for Flowmeter
  • Flow Totalizer for Flowmeter
  • Flow Totalizer for Flowmeter
  • Flow Totalizer for Flowmeter
  • Flow Totalizer for Flowmeter

Flow Totalizer for Flowmeter

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $60-200/ Piece
Port: Shanghai, China
Production Capacity: 5000 Set/Sets Per Month Flow Totalizer(96*96)
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Accuracy: 0.2%F.S
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size: Panel Size 96*96, Opening Size 92*92
Sensor: Matched with Flow Meter
Application: Energy Metering, Industrial Production
Type: Flow Totalizer

You Might Also Like

Loading...

Basic Info

Model NO.
GT-XSJ
Measuring Media
Vapor, Liquid, Gas
Measuring Principle
Electrical Principles
Measurement Object
Open Channels Closed Pipes
Certification
GB, CE, ISO
Flowmeter Type
The Velocity Type and The Volume Type Flowmeter
Keyword
Digital Display Meter Mechanical Flow Totalizer
Power Supply
24VDC or 85-220VAC
Input Signal
Pulse, 4-20mA, 0-5V
Output
RS485 Interfaces, 4-20mA, Alarm, Pulse
Function
for Gas Vapor Liquid Totalizer Measurement
Using Environment
- 30~+70degree (with LCD)
Custom Function
Customize Parameters According to Customer Needs
Trademark
JUJIE
Transport Package
Carton Packaging Filled Bubble Bags or Foam Boxes
Specification
96mm * 96mm
Origin
Shanghai, China
Flow Totalizer for Flowmeter
Flow Totalizer for Flowmeter
Flow Totalizer for Flowmeter

Product Overview
GT-XSJ series flow totalizer according to the temperature, pressure and flow rate of various signal acquisition, display, control, transmission, communication, printing processing, a digital acquisition control system. For gas, vapor, liquid totalizer, measurement and control.
GT-XSJ-M SERIES
                 GT-XSJ-M0            (Without temperature and pressure compensation)English characters display, with temperature and pressure compensation, with all the way alarm channel, 220VAC power supply / 12 ~ 24VDC power supply
GT-XSJ-M1English characters display,with temperature and pressure compensation, with one alarm channel, with isolated RS485 communication, 220VAC power supply / 12 ~ 24VDC power supply
GT- XSJ-M2English characters display,with temperature and pressure compensation, with all the way alarm channel, with U disk interface, 220VAC power supply / 12 ~ 24VDC power supply
GT-XSJ-M8English characters display,with temperature and pressure compensation, with all the way alarm channel, with all the way 4 ~ 20mA current output, 220VAC power supply / 12 ~ 24VDC power supply
GT-XSJ-M9English characters display, with temperature and pressure compensation, with one alarm channel, with isolated RS485 communication, with all the way 4 ~ 20mA current output, 220VAC power supply / 12 ~ 24VDC power supply
Performance Index
DescriptionSpecifications



Input Signal
Analog InputPulse Input
Thermocouple: K, E, B, J, N, T, SWaveform: Rectangular, Sine and Triangle wave
Pt100Amplitude: more than 4V
Current: 0-10mA, 4~20mA
Input impedance≤250Ω
Frequency: 0~10KHz
Special requirements please contact us




Output Signal
Analog OutputCommunication OutputSwitch OutputFeed Output
DC 0~10mA
(loadresistance ≤750Ω)
RS232, RS485, EthernetRelay with hysteresisDC24V (load current≤100mA)
DC 4~20mA (loadresistance ≤500Ω)Baud rate: 600, 1200, 2400, 4800, 9600bps,8 data bits, 1 stop bit, and 1 start bitAC220V/3A;
DC24V/6A(Resistive load)

 
DC12V (load current≤200mA)
Accuracy0.2%FS±1d or 0.5%FS±1d 
Accuracy for frequency conversion: ±1 pulse (LMS), better than 0.2%
Measuring Range-999999~999999 for flow rate and compensation value
0~99999999.9999 for totalizer
DisplayBacklit 128*64 lattice LCD
Display flow totalizer, flow rate, energy, power, medium temperature, medium pressure, medium density, medium heat enthalpy, differential pressure, current, frequency, date, time, Alarm status
Control/AlarmOptional relay upper limit and lower limit control (Alarm) output, LCD and LED output indication;
Control (Alarm) with hysteresis (The number of alarm relay is up to 2)
Alarm type: flow upper and lower limit, temperature upper and lower limit, pressure upper and lower limit
PrintThrough RS232 interface to Serial thermal printer 
Real-time print or timing print, Up to 8 times timing print in one day. 



Protection
Totalizer will be remained for more than 20 years after power off
Reset automatically when Power supply is low
Reset automatically when abnormal working (Watch Dog)
Self-healing fuse
Short circuit protection
Password protection for important data
Operating environmentAmbient temperature : -20~60ºC; Relative humidity: ≤85%RH, Far from strong corrosive gas

Power supply
Normal Type: AC 220V % (50Hz±2Hz)
Special Type: AC 80~265V (Switch power)
DC 24V±1V (Switch power) (AC 36V 50Hz±2Hz)
Back-up power: +12V, 20AH, it will last 72 hours
Power consumption≤10W


Main Features
1.Suitable for flow (Heat) displaying, calculating and controlling of all kinds of liquids, single or mixed gases and vapor.

2. Input multiple flow sensor signals (Such as VSF, Turbine, Electromagnetic, Roots, Elliptical gear, Duplex rotor, Orifice plate, V-cone, Annubar, and Thermal flowmeter, etc.).

3. Flow input channel: Receive frequency and multiple current signals.

4. Pressure and temperature input channel: Receive multiple current signals.

5. Provide 24VDC and 12VDC power supply with short circuit protection, simplify the system and save investment.

6. Fault-tolerance: When the compensation measurement signals of temperature, pressure or density are abnormal, compensate with the manual setting of the corresponding operation.

7. Circular display: Provide convenience to monitor multiple process variables.

8. The update cycle of output current signal is 1 second, which can meet the requirements of the automatic control.

9. Configure with Instrument clock, automatic meter reading and print function, provide convenience for metering management.

10. Self-test and self diagnosis make the instrument more easy to use and maintain.

11. 3 -level password to prevent unauthorized personnel to modify parameters.

12. There are no potentiometer, code switch and other adjustable devices, that can improve the vibration resistance, stability and reliability of the instrument.

13. Communication :RS485 ,RS232 ,GPRS/CDMA ,Ethernet

14. The USB interface can be configured to export the instrument data to the U disk.

15. Configure with temperature, pressure, and density compensations, and it also has compressibility coefficient compensation for general gas and flow nonlinear compensation.

16. Perfect function of vapor's density compensation, automatic recognition of saturated vapor and superheated vapor and moisture content calculation of wet vapor.

17. Special function for trade settlement.

A.Power down record

B.Timing meter reading

C.Query function on some illegal operations.

D.Printing 

18. Display unit can be modified according to different requirements.

19. Large storage function.

A.Day record can be stored in 5 years

B.Month record can be stored in 5 years

C.Year record can be stored in 16 years

Flow Totalizer for Flowmeter
Flow Totalizer for Flowmeter


 

Send your message to this supplier

*From:
*To:
avatar Mr. Leaf Cheng
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now